您可通過問題反饋或聯繫在線客服提交您的建議,我們將盡快完善:
Support
確定
??
-
我的賬號
註冊
忘記密碼?
български
čeština
Deutsch
English (United Kingdom)
English (United States)
español
français
italiano
日本語
한국어
polski
português
русский
Türkçe
中文
中文 (繁體)
CAD模型
不支持第三方 Cookie
您的瀏覽器不允許設置第三方 cookie。Please enable them in your browsers settings or click the button below.
請單擊此處在新選項卡中打開頁面內容。
If the opened page does not work initially, try reloading the page.
Please enable cookies in your browser for PARTcommunity to work
CAD模型
註冊
忘記密碼?
български
čeština
Deutsch
English (United Kingdom)
English (United States)
español
français
italiano
日本語
한국어
polski
português
русский
Türkçe
中文
中文 (繁體)
Catalog navigation
可提供的產品目錄語言:
čeština
dansk
Deutsch
English
español
suomi
français
italiano
Nederlands
polski
português
русский
slovenščina
svenska
English
QA認證資訊
目錄: Wilo
Created: 23.04.2019
產品目錄的特殊屬性:
Central management with the CADENAS quality tool PARTproject QA
Electronic test run was passed (CAD compatibility assured)
Only clear nomenclature -> ERP-compatibility assured
Wilo
4257992
Wilo
Pressure-boosting systems
SiBoost2.0 Smart Helix VE
Powered by
下載CAD模型
生成CAD模型
生成PDF資料表
Previews
3D
2D
CAD模型選擇
{wilo/40288a8a54ce361f0154de0868d9789c/8ae2819c8407a08701841358865f7099/8ae2819c84bc16420184d20eb3dc121b.prj},{NB=SiBoost2.0 Smart 4HELIX VE1003 4257992(350)_P1},{ARTICLE_ID=4257992},{EF021265=0},{EF023142=0},{EF023144=0},{EF000447=0},{EF020604=0},{EF023148=4},{EF014904=10.630},{EF014905=292.24},{EF000991=20.350},{EF000992=35.66},{EF020449=16.0},{EF000536=0},{EF003977=380},{EF000351=3},{EF000001=0.00},{EF012424=1.69},{EF012425=1.50},{EF001642=0},{EF007178=0},{EF007179=0},{EF016383=0},{EF016385=0},{EF016386=0},{EF016387=0},{EF016388=0},{EF016389=0},{EF016390=0},{EF003626=0},{EF007521=0},{EF003055=0},{EF003052=0},{EF007525=0},{EF016391=0},{EF016392=0},{EF016393=0},{EF016394=0},{EF016395=0},{EF016396=0},{EF016397=0},{EF023182=3.0},{EF002386=5.0},{EF025503=40},{EF025504=40},{EF023149=0},{LOD=350}
請根據技術需求選擇所需產品. 可選屬性在表格中高亮顯示. 選擇可以通過點擊表格或數值來重置.
可提供的產品: 34
HELP_VARIABLE
Company
Wilo
Description
4 Pumps
Bill of material
4257992
PRODUKTABBILDUNG
Produktabbildung
ARTICLE_ID
Article number
4257992
4257992
ARTICLE_NAME
Type code
SiBoost2.0 Smart 4HELIX VE1003
SiBoost2.0 Smart 4HELIX VE1003
LOD
Level Of Detail
350
300
200
350
300
200
MANUFACTURER_NAME
Manufacturer
WILO SE
DESCRIPTION_SHORT
Short text
Highly efficient water-supply unit ready for connection, with 2 to 4 vertically arranged, stainless steel, high-pressure multistage centrifugal pumps that are connected in parallel and non-self-priming from the Helix2.0 VE series; every pump is equipped with an integrated air-cooled frequency converter. System equipped with Smart Controller SCe2.0.
DESCRIPTION_LONG
Tender text
Compact pressure-boosting system according to DIN 1988 and DIN EN 806, for direct or indirect connection. Consisting of non-self-priming, connected in parallel, vertically-mounted stainless steel high-pressure multistage centrifugal pumps in glanded versions, for which each pump is fitted with a frequency converter. Ready for connection with stainless steel pipework, mounted on a base frame, including control device with all necessary measurement and adjustment equipment. *Fully automatic water distribution and boosting in residential, commercial and administrative buildings, hotels, hospitals, department stores and in the municipal water supply and industrial systems. Pumping of *Drinking water *Process water *Cooling water *Firefighting water (apart from fire-fighting systems in accordance with DIN 14462 and with the approval of the local fire protection authorities) or other types of industrial water that do not corrode the materials either chemically or mechanically and do not contain abrasive or long-fibre constituents. Special features/Product advantages *Heavy-duty system that fulfils all the requirements of DIN 1988 (EN 806) *WRAS/KTW/ACS approval of the pumps for all parts that come into contact with the fluid (EPDM version) *Helix2.0 VE series high-efficiency pump hydraulics, combined with IE5 EC motor drives, with air-cooled integral frequency converters *Optimum pump load adjustment due to pressure-variable (pv) control mode and parallel synchronous speed control for higher energy savings *Disproportionately large frequency converter control range of 25 Hz up to a maximum of 60 Hz saves energy *Integrated dry-running detection with automatic cut-out in event of low water via performance characteristics of the motor control electronics *Bidirectional mechanical seals in the pumps for easy maintenance *The flexible lantern design enables direct access to the mechanical seal *Hydraulics of entire system are pressure-loss optimised *Parts that come in contact with the fluid are corrosion-resistant *SCe2.0 control device, maximum degree of control performance with colour graphics display, simple navigation with clear menu, and Green Button Technology for setting parameters to control electronic pumps with frequency converters *Ready for integration into building automation with the SCe2.0 switchgear via standard-equipped Modbus TCP and BACnet IP (native), Modbus RTU and BACnet MS/TP via adapter from USB to RS485 *Factory testing and presetting to optimum working range Equipment/function *Helix2.0 VE2 to Helix2.0 VE52 series stainless steel high-pressure multistage centrifugal pump *Base frame made of electrolytically galvanised steel, with height-adjustable vibration absorbers for insulation against structure-borne noise On the discharge side: *Shut-off valve at each pump *Non-return valve at each pump *Diaphragm pressure vessel 8 l, PN 16 *2 pressure sensors 4 – 20 mA *Pressure gauge *Threaded cap or blind flange depending on the nominal diameter of the manifold on the suction side: *Shut-off valve at each pump *2 pressure sensors 4 – 20 mA *Pressure gauge *Threaded cap or blind flange depending on the nominal diameter of the manifold Automatic pump control via fully electronic Smart Controller (SCe2.0) in a sheet metal enclosure, protection class IP54, consisting of an internal control voltage supply unit, microprocessor with Soft PLC, analogue and digital inputs and outputs, for control of electronic pumps with frequency converters. A working area of 1 m around the system is recommended in order to facilitate the maintenance process. Operation/display *Colour graphics display to output operating data, controller parameters, operating statuses of the pumps, error messages and history memory *Menu navigation with plain text display and visualisation *Factory-preset parameters for easy commissioning/start *Setting of operating parameters and acknowledgement of fault messages using rotary knob *Lockable main switch *Operation with/without standby pump selectable *Elapsed time indicator for each pump and for the entire system *Switching cycle counter for each pump and for the entire system *Fault memory for the last 13 faults Control *Fully automatic control for 2 – 4 frequency-controlled pumps by means of setpoint/actual value comparison *Setpoint switchover: Second setpoint can be activated by contact *Automatic, load-sensitive cut-in of 1 to n peak-load pump(s) depending on the control variable “pressure constant” p-c or “pressure variable” p-v *Several user levels with different rights and menu scope *Operating mode of the pumps freely selectable (manual, off, automatic) *Automatic, configurable pump cycling **Standard setting: Impulse - The base-load pump is cycled at each new demand, regardless of operating hours **Alternative: Cyclical pump alteration of the base-load pump after the specified operating hours *Automatic, configurable pump test run (pump kick) **Can be activated/deactivated **Time between two pump test runs is freely programmable **Disabling times can be programmed as desired **Speed can be adjusted as desired Monitoring *Actual value of the system is output via a 0 – 10 volt analogue signal for external measurement/display applications, 10 volt depending on the sensor range value *4 – 20 mA sensor signal (conductivity test of the sensor cable) for control variable actual value *The pump mains power feed is protected via the circuit breaker *Automatic switchover to standby pump in the event of an operating pump fault *Monitoring of maximum and minimum system values with adjustable time delays and limits *Zero-flow test for switching off the system when no water is being drawn off (adjustable parameters) *Pipe filling function for filling empty pipes (initial filling of the consumer network) *Protection against low water level via contact, e.g. for float switch or pressure switch *Automatic shutdown of pumps if fault occurs or operation at preset emergency operation speed Interfaces *Potential-free contacts for SBM/SSM collective run and collective fault signals *Logic reversal can be applied to SBM and SSM *Contacts for external On/Off, low water and second setpoint *External On/Off via contact for deactivation of the system's automatic mode Optional accessories (factory fit or retrofitting after technical checks) *Individual operation/fault message *Signal converter for 0/2 – 10 V to 0/4 – 20 mA *Pressure switch for protection against low water level Optional accessories (provided by the customer) *Pressure switch for redundant protection against low water level Recommended accessories (to be ordered separately) *Flexible connection pipes or compensators *Diaphragm pressure vessel on the suction or end pressure side according to the conditions or requirements Bus systems (optional) *Modbus RTU, BACnet MSTP Standards followed *Specifications for drinking water installations (TRWI) DIN 1988 (EN 806) *Diaphragm pressure vessel/diaphragm expansion tank DIN 4807 *Electronic equipment for use in power installations EN 50178 *Electrical equipment of machines EN 60204-1 *Safety of household and similar electrical appliances EN 60335-1 *Low-voltage switchgear and controlgear assemblies EN 60439-1/61439-1 *Electromagnetic compatibility (EMC) — Interference emission for residential, commercial and light-industrial environments (EN 61000-6-3)
PRODUCT_DESCRIPTION
Product description
SiBoost2.0 Smart 4HELIX VE1003
SiBoost2.0 Smart 4HELIX VE1003
ETIM_CLASS__EC_
ETIM Class (EC)
EC010737
EF021265
Suitable for tap water
0
EF024284
Suitable for rainwater
false
EF025120
Suitable for sprinkling/irrigation
false
EF023038
Pump casing material
Stainless steel
EF023143
Quality class of pump casing
X5CrNi18-10
EF011652
Material pump wheel
Stainless steel
EF024149
Material pump wheel
X2CrNi18-9
EF023142
Material fittings
0
EF023144
Material fittings
0
EF023489
Material of unit pipework
Stainless steel
EF023488
Quality class of unit pipework
X2CrNi18-9
EF000447
Reservoir material
0
EF020604
Quality class of reservoir
0
EF023148
Number of pumps
4
EF014904
Volume flow rate (BEP)
10.630
10.630
m³/h
EF014905
Head at flow rate (BEP)
292.24
292.24
kPa
EF000991
Max. discharge flow
20.350
20.350
m³/h
EF000992
Max. static height
35.66
35.66
m
EF020449
Max. operating pressure
16.0
bar
EF003701
Electrical connection
0
EF000536
Cable length
0
mm
EF003977
Rated voltage
380
380
V
EF000351
Number of phases
3
3
EF005455
Frequency
50. 60
Hz
EF000001
Nominal current
0.00
A
EF012424
Motor power input (P1) per motor
1.69
1.69
kW
EF012425
Motor power output (P2) per motor
1.50
1.50
kW
EF023092
Insulation class acc. to IEC
F
EF001642
Rotational speed
0
1/min
EF020121
Motor speed control
Built-in
EF020120
Type of speed control
0
EF015266
Communication
0
EF007178
Radio standard Bluetooth
0
EF007179
Radio standard 2G / 3G / 4G
0
EF016383
Radio standard 2G / 3G / 4G
0
EF016385
Radio standard 5G
0
EF016386
Interface signal 0-10 V / 2-10 V
0
EF016387
Interface signal 0-20 mA / 4-20 mA
0
EF016388
Interface PT100 / PT1000 / PTC
0
EF016389
Interface Pulse Width Modulation (PWM)
0
EF016390
Interface pulse counter
0
EF003626
Potential free switch contact
0
EF007314
With communication interface RS-485
0
EF007312
With communication interface RS-232
0
EF007521
Supporting protocol for EtherNet/IP
0
EF003055
Supporting protocol for KNX
0
EF003052
Supporting protocol for PROFIBUS
0
EF007525
Supporting protocol for PROFINET IO
0
EF016391
Supporting protocol for CAN/CANOpen
0
EF016392
Supporting protocol for Modbus TCP
0
EF016393
Supporting protocol for Modbus RTU
0
EF016394
Supporting protocol for BACnet MS/TP
0
EF016395
Supporting protocol for BACnet IP
0
EF016396
Supporting protocol for LON/LONWorks
0
EF016397
Supporting protocol for LIN Bus
0
EF023182
Medium temperature (continuous)
3.0
°C
EF002386
Ambient temperature
5.0
°C
EF025116
Connection on supply side
Oval flange;Oval-G1½-PN16-DIN-ISO228-1
Oval flange;Oval-G1½-PN16-DIN-ISO228-1
EF025117
Diameter of connection on supply side
G 1½
G 1½
EF025503
Outer pipe diameter connection inlet side
40
40
mm
EF026143
Flange compression stage connection inlet
PN 16
bar
EF014906
Connection standard inlet side
DIN ISO 228-1
DIN ISO 228-1
EF025977
Connection outlet side
Oval flange;Oval-G1½-PN16-DIN-ISO228-1
Oval flange;Oval-G1½-PN16-DIN-ISO228-1
EF025118
Diameter of connection on delivery side
G 1½
G 1½
EF025504
Outer pipe diameter connection outlet side
40
40
mm
EF026233
Flange compression stage connection outlet
PN 16
bar
EF014907
Connection standard outlet side
DIN ISO 228-1
DIN ISO 228-1
EF001339
Flange shape
Oval flange
Oval flange
EF023149
Suction installation
0
EF023154
With bypass pipe
0
EF026396
Degree of protection (IP) pump
IP55
EF026395
Degree of protection cabinet (IP)
IP54
EF001438
Length
1450.0
1450.0
mm
EF000008
Width
890.0
890.0
mm
EF000040
Height
1045.0
1045.0
mm
EF000167
Weight
251.0
251.0
kg
EF008837
Approval
0
A1
Angle to first bolt hole
0.0
0.0
°
A2
Angle to first bolt hole
0.0
0.0
°
A3
Angle to first bolt hole
0.0
0.0
°
A4
Angle to first bolt hole
0.0
0.0
°
B1
Thickness flange (incl. sealing edge)
0
0
mm
B2
Thickness flange (incl. sealing edge)
0
0
mm
B3
Thickness flange (incl. sealing edge)
0
0
mm
B4
Thickness flange (incl. sealing edge)
0
0
mm
D1
Outer diameter of flange
0
0
mm
D2
Outer diameter of flange
0
0
mm
D3
Outer diameter of flange
0
0
mm
D4
Outer diameter of flange
0
0
mm
D21
Diameter bolt hole
0
0
mm
D22
Diameter bolt hole
0
0
mm
D23
Diameter bolt hole
0
0
mm
D24
Diameter bolt hole
0
0
mm
D41
Diameter sealing edge
0
0
mm
D42
Diameter sealing edge
0
0
mm
D43
Diameter sealing edge
0
0
mm
D44
Diameter sealing edge
0
0
mm
DE
Diameter expansion vessel
206
mm
DM
Diameter motor
145.0
145.0
mm
DN1
Diameter of connection on supply side
R 3
R 3
mm
DN2
Diameter of connection on supply side
R 3
R 3
mm
DN3
Diameter of connection on delivery side
R 3
R 3
mm
DN4
Diameter of connection on delivery side
R 3
R 3
mm
DO1
Outer pipe diameter connection inlet side
0.0
DO2
Outer pipe diameter connection inlet side
0.0
DO3
Outer pipe diameter connection outlet side
0.0
DO4
Outer pipe diameter connection outlet side
0.0
F1
Thickness sealing edge
0.0
0.0
mm
F2
Thickness sealing edge
0.0
0.0
mm
F3
Thickness sealing edge
0.0
0.0
mm
F4
Thickness sealing edge
0.0
0.0
mm
H
Height
1045
1045
mm
H02
Distance to bottom side vessel
248
248
mm
H1
Height to centre connection
170
170
mm
H2
Height to centre connection
170
170
mm
H3
Height to centre connection
170
170
mm
H4
Height to centre connection
170
170
mm
H5
Height expansion vessel
297
mm
H6
Height electrical cabinet
950
mm
HP
Pump height
849
849
mm
K1
Pitch circle
0
0
mm
K2
Pitch circle
0
0
mm
K3
Pitch circle
0
0
mm
K4
Pitch circle
0
0
mm
L
Length of foundation plate
1450
1450
mm
L1
Connection length
150
150
mm
L2
Connection length
1050
1050
mm
L3
Connection length
150
150
mm
L4
Connection length
1050
1050
mm
LE1
Distance till side foundation plate
350
350
mm
LE2
Centre-to-centre (double) pump
300
300
mm
LE3
Thickness electrical cabinet
400
400
mm
LE4
Width electrical cabinet
150
mm
LE5
Length to top side electrical cabinet
240.0
240.0
mm
LE6
Length electrical cabinet
316.7
316.7
mm
LE7
Distance to side cabinet
0
mm
LE8
Width electrical cabinet 1
267.4
267.4
mm
LE9
Length 9
30
mm
N1
Number of bolt holes
0
0
N2
Number of bolt holes
0
0
N3
Number of bolt holes
0
0
N4
Number of bolt holes
0
0
NP
Number of pumps
4
Q1
Length gusset/thread
25
25
mm
Q2
Length gusset/thread
25
25
mm
Q3
Length gusset/thread
25
25
mm
Q4
Length gusset/thread
25
25
mm
S1
Wall thickness connection
5
5
mm
S2
Wall thickness connection
5
5
mm
S3
Wall thickness connection
5
5
mm
S4
Wall thickness connection
5
5
mm
W1
Centre-to-centre distance of connections
730
730
mm
W2
Foundation plate width
420
mm
W3
Distance backside cabinet
0
HD
Diameter pump housing
152
152
mm
H01
Dimensions
90
90
mm
L5
Dimensions
300
300
mm
W0
Dimensions
890
890
mm